left image
right image

Product Photos

 xmulargefront120px
 xmulargeback120px

Products - ATIS XMU+ Specifications

ATIS XMU+

Automatic Terminal Information System


Product Specifications

  

Audio Inputs:

  Tape: 10K ohms (1/4"phone jack)
  Remote access jack (RJ11 for PSTN or PBX connection)

Audio Storage:

  Voice encoding/decoding
  Pulse code modulation (PCM)
  Storage medium: SDRAM and FLASH
  Storage rate: 8 kHz x 8 bit bytes/sec (64K digital bandwidth)
  Frequency response: 300 Hz to 3.4 kHz (+/- 3 dB)
  From 8 minutes to 6 hours of recording time

Alarm Contacts:

  2 output contacts (universal)
  2 inputs (12-60v voltage sensing contact closure)

Communication Ports:

  2 RS-232 port (RJ-45)
  1 Ethernet port (RJ45)
  1 V9.2 Modem port (RJ11)

Programming Options:

  Via front panel
  Via XMUCOM+ Software

Messages:

  999 messages per partition
  64 partitions
  Messages cannot exceed total recording time

Message Transmission:

  Outgoing message plays continuously to transmitter output

Audio Storage/Reproduction:

  Audio messages can be recorded remotely,
    or via an optional ring-down circuit

Signal To Noise Ratio:

  50 dB at 1 KHz

XMU+ Large Power Supply:

  110/240 VAC, 1.0/0.5 A, 60/50 Hz, 120 W
  -48 VDC, 2.5 A, 120 W

XMU+ Small Power Supply:

  110/240 VAC, 0.4/0.2 A, 60/50 Hz, 40 W

Approvals:

•  FCC, CS-03, NRTL/C, CE, cCSAus

XMU+ Large Dimensions:

•  7 in. (17.5 cm) Height x 17.5 in. (44 cm) Width x 12 in. (31 cm) Depth

XMU+ Small Dimensions:

  1.75 in. (4.38 cm) Height x 17.5 in. (44 cm) Width x 12 in. (31 cm) Depth

Temperature Range:

  Storage: 0 to +60 degrees C
  Operating: +10 to +40 degrees C

Relative Humidity:

  Storage: 10% to 90%
  Operating: 10% to 90%

Message Administration:

  Option 1: Via handset directly from the control tower
  Option 2: Remote-ring down directly to the ATIS
  Option 3: Remote access over the telephone
  Option 4: Air/ground voice switch integration
  Option 5: TCP/IP

ATIS (XMU+) Line Card:

  Option 1: Four balanced 600 ohm outputs as
     transmitter or monitor outputs
  Option 2: Four balanced 600 ohm outputs as
     transmitter or monitor outputs plus four PSTN (Telephone) lines

Keying The Transmitters:

  Phantom PTT (Voltage Keying) internal or external power options
  A dry contact closure is used to enable/disable each transmitter port.

Available Contact Options:

  Normally Open
  Normally Closed

Transmitter Outputs:

  Up to 4 balanced 600 ohm outputs
  Unique message plays to each output
  Output Level: -10 dBm to +2 dBm at 600 ohm

Monitor Outputs:

  Up to 2 balanced 600 ohm outputs to monitor a transmitter output
  Output Level: -10 dBm to +2 dBm at 600 ohm

XMUCOM+ Administration Software:

  Windows 98, 2000 or XP
  Support for .wav files
  Remotely manage 1000 XMU+ units or more
  Download configurations via windows

Note: Specifications are approximate and are subject to change.